BOARD ID = "DEL0001" NAME="Dell System(R) 425E(TM) System Board" MFR="Dell Computer Corporation" CATEGORY = "SYS" SLOT = EMB(0) READID = YES SIZING = 0 SYSTEM NONVOLATILE = 8192 AMPERAGE = 15000 SLOT(1) = EISA LENGTH = 341 LABEL="EXP1" SLOT(2) = EISA LENGTH = 341 LABEL="EXP2" SKIRT=NO SLOT(3) = EISA LENGTH = 341 LABEL="EXP3" SKIRT=NO SLOT(4) = EISA LENGTH = 341 LABEL="EXP4" SLOT(5) = EISA LENGTH = 341 LABEL="EXP5" SLOT(6) = EISA LENGTH = 341 LABEL="EXP6" SLOT(7) = ISA16 LENGTH = 341 LABEL="EXP7" SLOT(8) = ISA16 LENGTH = 341 LABEL="EXP8" MEMORY = 256M ADDRESS = 0 CACHE = YES STEP = 32K ;-------------------------------- ; Dell System Board Jumpers ;-------------------------------- JUMPER(1) = 1 JTYPE = PAIRED NAME= "JM2" VERTICAL = YES LABEL = LOC(1) "MAINT JM2" INITVAL = LOC(1) 0 FACTORY = LOC(1) 0 COMMENTS = "Factory Test Jumper\n Jumper JM2 is used during the manufacture of the Dell System 425E to test the basic input/output system (BIOS) software. Thereafter, its pins are left open (unjumpered). Do not install a jumper plug on the JM2 pins unless instructed to do so by a Dell service technician." FUNCTION = "Factory Test Jumper" SHOW = NO CHOICE = "Normal" JUMPER(3) = 2 JTYPE = INLINE NAME= "JM1" VERTICAL = NO INITVAL = LOC(3^2 2^1) 10 FACTORY = LOC(3^2 2^1) 10 COMMENTS = "Monitor-Type Jumper\n Jumper JM1 indicates the primary display when both monochrome and CGA video cards are installed. For a color monitor, pins 2 and 3 are jumpered; for a monochrome monitor, pins 1 and 2 are jumpered. The function of jumper JM4 is better handled through the System Setup program. Use the \"Display\" category to select the primary display in computer systems that have both monochrome and color graphics adapter (CGA) video boards. For all other computer systems, ignore this category." FUNCTION = "Monitor Type Jumper" SHOW = NO CHOICE = "Normal" JUMPER(4) = 1 JTYPE = PAIRED NAME= "J20" VERTICAL = YES LABEL = LOC(1) "RESET J20" INITVAL = LOC(1) 0 FACTORY = LOC(1) 0 COMMENTS = "Factory Reset Jumper\n Jumper J20 is normally open (unjumpered). Trained, qualified technicians can use this jumper to reset the system when it does not reboot normally or respond to the keyboard. Do not install a jumper plug on the J20 pins unless instructed to do so by a Dell service technician." FUNCTION = "Factory Reset Jumper" SHOW = NO CHOICE = "Normal" JUMPER(2) = 4 JTYPE = PAIRED NAME= "J26" VERTICAL = NO LABEL = LOC(4-1) "D" "C" "B" "A" FACTORY = LOC(4-1) 1111 COMMENTS = "Memory Configuration Jumpers\n Jumper J26 is used to indicate whether 1-MB or 2-MB single in-line memory modules (SIMMs) are installed in each of the four banks of SIMM sockets. A jumper plug is installed for each bank containing 1-MB SIMMs; no jumper plug is installed for each bank containing 2-MB SIMMs. A jumper has no effect if SIMMs are not installed in the corresponding bank. The factory setting for a bank with no SIMMs is to have a jumper plug installed (jumpered) in case you later want to add 1-MB SIMMs." INCLUDE = "DELSETUP.OVL" GROUP = "Advanced Features" FUNCTION="BIOS Caching" COMMENTS="For better system performance, leave BIOS caching enabled unless told to disable it by a Dell service technician.\n" SHOW = EXP CHOICE="Enable" FREE MEMORY=64k ADDRESS=0F0000h MEMTYPE=OTHER WRITABLE=NO CACHE=YES CHOICE="Disable" FREE MEMORY=64k ADDRESS=0F0000h MEMTYPE=OTHER WRITABLE=NO CACHE=NO FUNCTION = "Fail-Safe Timer NMI" COMMENTS = "This option enables or disables the generation of a fail-safe timer non-maskable interrupt (NMI).\n" SHOW = EXP CHOICE = "Disable" DISABLE=YES FREE INIT = PORTADR(0461h) BYTE rrrrr0rr CHOICE = "Enable" FREE INIT = PORTADR(0461h) BYTE rrrrr1rr FUNCTION = "Bus-Master Timeout NMI" COMMENTS = "This option enables or disables the generation of a bus-master timeout non-maskable interrupt (NMI).\n" SHOW = EXP CHOICE = "Disable" DISABLE=YES FREE INIT = PORTADR(0461h) BYTE rrrr0rrr CHOICE = "Enable" FREE INIT = PORTADR(0461h) BYTE rrrr1rrr FUNCTION = "Software Generated NMI" COMMENTS = "This option enables or disables the generation of a software non-maskable interrupt (NMI).\n" SHOW = EXP CHOICE = "Disable" DISABLE=YES FREE INIT = PORTADR(0461h) BYTE rrrrrr0r CHOICE = "Enable" FREE INIT = PORTADR(0461h) BYTE rrrrrr1r ENDGROUP