; ;SP-274 Configuration File Ver 1.84 Date : Feb 26, '93. ; BOARD ID="IDS0201" NAME="ScsiPro SP-274 EISA SCSI Host Adapter" MFR="SCSIPRO." CATEGORY="MSD" SLOT=EISA LENGTH=330 AMPERAGE=1000 SKIRT=NO READID=YES BUSMASTER=100 IOCHECK=VALID DISABLE=SUPPORTED COMMENTS ="SP-274 Configuration File Ver 1.84" IOPORT(1)=0zc92h ; Card Mode INITVAL=0000000x IOPORT(2)=0zc93h ; IRQ INITVAL=0000xxxx IOPORT(3)=0zc94h ; BasePort >> 2 INITVAL=xxxxxxxx IOPORT(4)=0zc95h ; (BIOS seg - 0xc000) / 0x400 INITVAL=0000xxxx IOPORT(5)=0zc96h ; HA Id INITVAL=00000xxx IOPORT(6)=0zc97h ; Greater 2 Disks support INITVAL=0000000x IOPORT(7)=0zc98h ; SYNC ON/OFF INITVAL=xxxxxxxx IOPORT(8)=0zc99h INITVAL=0000000x ; PARITY ON/OFF IOPORT(9)=0zc9ah INITVAL=xxxxxxxx ; Number of heads IOPORT(10)=0zc9bh INITVAL=xxxxxxxx ; SPT IOPORT(11)=0zc9ch INITVAL=xxxxxxxx ; DMA IOPORT(12)=0zc8bh INITVAL=xxxxxxxx ; SEMA_1 IOPORT(13)=0zc8bh INITVAL=xxxxxxxx ; SEMA_1 IOPORT(14)=0zc9dh INITVAL=xxxxxxxx ; signature IOPORT(15)=0zc90h INITVAL=xxxxxxxx ; PICK ECU command IOPORT(16)=0zc8dh INITVAL=xxxxxxxx ; LINT FUNCTION = "Host Interface" SUBFUNCTION = "Operation mode" COMMENTS="This selection sets the mode in which the SP-274 will operate. Most operating systems carry device drivers which can work with the SP-274 when it is in COMPATIBLE mode.\n \nSelect ENHANCED mode when\n \t1. You wish to use the SP-274 device drivers.\n \t2. Your system memory is more than 16 Megabytes.\n \t3. You have more than one SP-274 in the system.\n \nThe SP-274 performs faster in ENHANCED mode." CHOICE = "COMPATIBLE mode" LINK INIT= IOPORT(1) LOC(0) 0 INIT= IOPORT(12) LOC(0) 0 CHOICE = "ENHANCED mode" LINK INIT= IOPORT(1) LOC(0) 1 INIT= IOPORT(12) LOC(0) 1 SUBFUNCTION = "I/O Port" COMMENTS = "The SP-274 uses a set of four I/O Port addresses in COMPATIBLE mode operation.\n Select the Host Adapter base port address for compatible mode operation. The SP-274 does not use I/O port when operating in the ENHANCED mode. DISABLE the I/O Port if you have set the Operation mode of SP-274 as ENHANCED." CHOICE = " 330H" LINK PORT = 330H-333H SHARE=YES SIZE=BYTE INIT=IOPORT(3) LOC (7-0) 11001100B INIT= IOPORT(13) LOC(0) 1 CHOICE = " 230H" LINK PORT = 230H-233H SHARE=NO SIZE=BYTE INIT=IOPORT(3) LOC (7-0) 10001100B INIT= IOPORT(13) LOC(0) 0 CHOICE = " 130H" LINK PORT = 130H-133H SHARE=NO SIZE=BYTE INIT=IOPORT(3) LOC (7-0) 01001100B INIT= IOPORT(13) LOC(0) 0 CHOICE = " 334H" LINK PORT =334H-337H SHARE=NO SIZE=BYTE INIT=IOPORT(3) LOC (7-0) 11001101B INIT= IOPORT(13) LOC(0) 0 CHOICE = " 234H" LINK PORT = 234H-237H SHARE=NO SIZE=BYTE INIT=IOPORT(3) LOC (7-0) 10001101B INIT= IOPORT(13) LOC(0) 0 CHOICE = " 134H" LINK PORT = 134H-137H SHARE=NO SIZE=BYTE INIT=IOPORT(3) LOC (7-0) 01001101B INIT= IOPORT(13) LOC(0) 0 CHOICE = " Disabled (Enhanced Mode)" ; DISABLE = YES FREE INIT=IOPORT(3) LOC (7-0) 00000000B INIT= IOPORT(13) LOC(0) 0 SUBFUNCTION = "Interrupt channel" COMMENTS = "\nSelect the interrupt channel number which will be used by this SP-274.\nMake sure no other adapter uses the same channel. \n\nThe SP-274 uses same interrupt channel for both modes of operation." CHOICE = "IRQ 11" LINK IRQ = 11 INIT= IOPORT(2) LOC(3-0) 1011 CHOICE = "IRQ 9" LINK IRQ = 9 INIT= IOPORT(2) LOC(3-0) 1001 CHOICE = "IRQ 10" LINK IRQ = 10 INIT= IOPORT(2) LOC(3-0) 1010 CHOICE = "IRQ 12" LINK IRQ = 12 INIT= IOPORT(2) LOC(3-0) 1100 CHOICE = "IRQ 14" LINK IRQ = 14 INIT= IOPORT(2) LOC(3-0) 1110 CHOICE = "IRQ 15" LINK IRQ = 15 INIT= IOPORT(2) LOC(3-0) 1111 SUBFUNCTION = "DMA Channel" COMMENTS = "\nThis option selects the DMA channel to be reported to standard operating system drivers by the SP-274 in COMPATIBLE mode.\n \nDMA channel is not required in ENHANCED mode. For enhanced mode operation this option should be DISABLED.\n" CHOICE = "DMA 5" LINK DMA = 5 SHARE = YES INIT=IOPORT(11) LOC(7-0) 00100000B CHOICE = "DMA 6" LINK DMA = 6 SHARE = YES INIT=IOPORT(11) LOC(7-0) 01000000B CHOICE = "DMA 7" LINK DMA = 7 SHARE = YES INIT=IOPORT(11) LOC(7-0) 10000000B CHOICE = "DMA 0" LINK DMA = 0 SHARE = YES INIT=IOPORT(11) LOC(7-0) 00000001B CHOICE = "Disabled (Enhanced Mode)" ; DISABLE = YES FREE INIT=IOPORT(11) LOC(7-0) 00000000B FUNCTION="SCSI Interface" SUBFUNCTION="SCSI ID" COMMENTS ="This option selects the initiator SCSI ID of the SP-274. Each device on SCSI bus must have a unique SCSI ID. Do not set the SCSI ID of any SCSI peripheral connected to this SP-274, same as initiator SCSI ID of the SP-274. The EISA configuration utility can not detect SCSI bus conflicts." CHOICE="ID 7" FREE INIT=IOPORT(5) LOC(2-0) 111 CHOICE="ID 6" FREE INIT=IOPORT(5) LOC(2-0) 110 CHOICE="ID 5" FREE INIT=IOPORT(5) LOC(2-0) 101 CHOICE="ID 4" FREE INIT=IOPORT(5) LOC(2-0) 100 CHOICE="ID 3" FREE INIT=IOPORT(5) LOC(2-0) 011 CHOICE="ID 2" FREE INIT=IOPORT(5) LOC(2-0) 010 CHOICE="ID 1" FREE INIT=IOPORT(5) LOC(2-0) 001 CHOICE="ID 0" FREE INIT=IOPORT(5) LOC(2-0) 000 SUBFUNCTION="SCSI Parity" COMMENTS="\n\nThe SP-274 Host adapter performs data parity checking on SCSI transfers.\n\n\n If a SCSI peripheral does not support parity then the parity checking on the SP-274 must be disabled.\n\n\n" CHOICE="Enabled" FREE INIT=IOPORT(8) LOC(0) 1 CHOICE="Disabled" FREE INIT=IOPORT(8) LOC(0) 0 FUNCTION = "SCSI AUTO Synchronous Negotiation" COMMENTS = "SCSI Auto Synchronous Negotiation can be enabled or disabled on a SCSI Target Basis." HELP = "SCSI Auto Synchronous Negotiation can be enabled or disabled on a SCSI Target Basis. If enabled the SP-274 will initiate Synchronous negotiation with that Target ID. If disabled the SP-274 will not initiate this negotiation, but will still respond to synchronous negotiation if initiated by the SCSI Target device." SUBFUNCTION = "SCSI ID 7" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(7) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(7) 0 SUBFUNCTION = "SCSI ID 6" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(6) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(6) 0 SUBFUNCTION = "SCSI ID 5" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(5) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(5) 0 SUBFUNCTION = "SCSI ID 4" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(4) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(4) 0 SUBFUNCTION = "SCSI ID 3" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(3) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(3) 0 SUBFUNCTION = "SCSI ID 2" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(2) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(2) 0 SUBFUNCTION = "SCSI ID 1" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(1) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(1) 0 SUBFUNCTION = "SCSI ID 0" CHOICE = "ENABLE" FREE INIT = IOPORT(7) LOC(0) 1 CHOICE = "DISABLE" FREE INIT = IOPORT(7) LOC(0) 0 FUNCTION = "BIOS Configuration" SUBFUNCTION = "SCSI BIOS address" COMMENTS = "The SP-274 BIOS can be enabled or disabled. When the BIOS is enabled, make sure that its address in memory does not conflict with any other resource in the system.\n When you have more than one SP-274 in the system ENABLE the BIOS of the SP-274 inserted in lowest slot number and DISABLE the BIOS of remaining SP-274 adapters." CHOICE=" DC000H" COMBINE MEMORY=16K ADDRESS=0DC000H WRITABLE=NO MEMTYPE = OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=32 INIT=IOPORT(4) LOC(3-0) 0111B CHOICE=" D8000H" COMBINE MEMORY=16K ADDRESS=0D8000H WRITABLE=NO MEMTYPE = OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=32 INIT=IOPORT(4) LOC(3-0) 0110B CHOICE=" D4000H" COMBINE MEMORY=16K ADDRESS=0D4000H WRITABLE=NO MEMTYPE = OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=32 INIT=IOPORT(4) LOC(3-0) 0101B CHOICE=" D0000H" COMBINE MEMORY=16K ADDRESS=0D0000H WRITABLE=NO MEMTYPE = OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=32 INIT=IOPORT(4) LOC(3-0) 0100B CHOICE=" CC000H" COMBINE MEMORY=16K ADDRESS=0CC000H WRITABLE=NO MEMTYPE = OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=32 INIT=IOPORT(4) LOC(3-0) 0011B CHOICE=" C8000H" COMBINE MEMORY=16K ADDRESS=0C8000H WRITABLE=NO MEMTYPE = OTH SHARE=NO SIZE=BYTE CACHE=YES DECODE=32 INIT=IOPORT(4) LOC(3-0) 0010B CHOICE = "BIOS disabled" DISABLE = yes FREE INIT=IOPORT(4) LOC(3-0) 1111B SUBFUNCTION = "Handle more than two disks" COMMENTS = "\nMS-DOS 5 has drivers to access more than two hard disks.For this the SCSI BIOS has to handle more than two hard disks.\n\nThe SP-274 BIOS can handle more than two hard disks through INT 13H if you ENABLE this option.\n\nDisable this option if you wish to access removable disks or if you are not using MS-DOS 5.\n\n" CHOICE="Disabled" FREE INIT=IOPORT(6) LOC(0) 0B CHOICE="Enabled" FREE INIT=IOPORT(6) LOC(0) 1B SUBFUNCTION = "Hard disk format" COMMENTS = "The SP-274 supports two hard disk formats. When the disk capacity is less than 1 Gigabytes or you plan to use SCO Unix, keep the hard disk format as 64 HD x 32 Sectors. This will allow you to access hard disks formatted & installed by most SCSI adapters without re-formatting.\n\n If the disk capacity is more than 1 Gigabytes, select the hard disk format as 255 HD x 63 Sectors.\n\n CAUTION: YOU MUST RE-INITIALIZE THE HARD DISKS IF YOU HAVE\n\tCHANGED THE HARD DISK FORMAT." CHOICE=" 64 HD x 32 Sectors (up to 1 GB)" LINK INIT=IOPORT(9) LOC(7-0) 01000000B INIT=IOPORT(10) LOC(7-0) 00100000B INIT=IOPORT(14) LOC(7-0) 01010101B INIT=IOPORT(15) LOC(7-0) 00001101B INIT=IOPORT(16) LOC(7-0) 00000010B CHOICE=" 255 HD x 63 Sectors" LINK INIT=IOPORT(9) LOC(7-0) 11111111B INIT=IOPORT(10) LOC(7-0) 00111111B INIT=IOPORT(14) LOC(7-0) 01010101B INIT=IOPORT(15) LOC(7-0) 00001101B INIT=IOPORT(16) LOC(7-0) 00000010B ;end of file