BOARD ID="ISA4020" NAME="GammaLink Fax Card Adapter Definitions" MFR="Dialogic" CATEGORY="OTH" SLOT=ISA16 LENGTH=100 COMMENTS="Use this for GammaLink CP6/SC and CP12/SC Modules.\n The GammaLink CP6/SC (or CP12/SC) module provides 6 (or 12) FAX channels that transmit and receive over the Dialogic SCbus.\n" FUNCTION="CP6/CP12 - I/O RANGE 0" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 1 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=350h-353h PORT=360h-363h PORT=370h-373h PORT=250h-253h PORT=260h-263h PORT=270h-273h PORT=358h-35Ch CHOICE="CP12" LINK PORT=350h-353h PORT=360h-363h PORT=370h-373h PORT=250h-253h PORT=260h-263h PORT=270h-273h PORT=150h-153h PORT=160h-163h PORT=170h-173h PORT=104h-10fh PORT=358h-35Ch FUNCTION="CP6/CP12 - I/O RANGE 1" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 2 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=150h-153h PORT=160h-163h PORT=170h-173h PORT=104h-10fh PORT=158h-15Ch CHOICE="CP12" LINK PORT=150h-153h PORT=160h-163h PORT=170h-173h PORT=104h-10fh PORT=110h-11fh PORT=280h-287h PORT=158h-15Ch FUNCTION="CP6/CP12 - I/O RANGE 2" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 3 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=110h-11Fh PORT=280h-287h PORT=168h-16Ch CHOICE="CP12" LINK PORT=110h-11Fh PORT=280h-29Fh PORT=168h-16Ch FUNCTION="CP6/CP12 - I/O RANGE 3" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 4 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=288h-29Fh PORT=140h-144h CHOICE="CP12" LINK PORT=288h-29Fh PORT=120h-137h PORT=140h-144h FUNCTION="CP6/CP12 - I/O RANGE 4" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 5 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=120h-137h PORT=148h-14ch CHOICE="CP12" LINK PORT=120h-13Fh PORT=180h-18Fh PORT=148h-14ch FUNCTION="CP6/CP12 - I/O RANGE 5" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 6 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=138h-13Fh PORT=180h-18Fh PORT=2B0h-2B4h CHOICE="CP12" LINK PORT=138h-13Fh PORT=180h-1A7h PORT=2B0h-2B4h FUNCTION="CP6/CP12 - I/O RANGE 6" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 7 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=190h-1A7h PORT=2b8h-2bch CHOICE="CP12" LINK PORT=190h-1BFh PORT=2b8h-2bch FUNCTION="CP6/CP12 - I/O RANGE 7" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 8 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=1A8h-1BFh PORT=2C0h-2C4h CHOICE="CP12" LINK PORT=1A8h-1D7h PORT=2C0h-2C4h FUNCTION="CP6/CP12 - I/O RANGE 8" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 9 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=1C0h-1D7h PORT=2c8h-2cch CHOICE="CP12" LINK PORT=1C0h-1EFh PORT=2c8h-2cch FUNCTION="CP6/CP12 - I/O RANGE 9" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range A must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=1D8h-1EFh PORT=2d0h-2d4h CHOICE="CP12" LINK PORT=1D8h-1EFh PORT=2d0h-2d4h PORT=254h-25fh PORT=264h-267h PORT=300H-307H FUNCTION="CP6/CP12 - I/O RANGE A" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range B must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=254h-25fh PORT=264h-267h PORT=300H-307H PORT=320H-324H CHOICE="CP12" LINK PORT=254h-25fh PORT=264h-267h PORT=300H-307H PORT=308h-31fh PORT=220H-234H FUNCTION="CP6/CP12 - I/O RANGE B" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range C must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=308h-31fh PORT=3C8H-3CCH CHOICE="CP12" LINK PORT=308h-31fh PORT=330h-347h PORT=3C8H-3CCH FUNCTION="CP6/CP12 - I/O RANGE C" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range D must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=330h-347h PORT=328H-32CH CHOICE="CP12" LINK PORT=330h-347h PORT=348h-34fh PORT=380h-38fh PORT=328H-32CH FUNCTION="CP6/CP12 - I/O RANGE D" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range E must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=348h-34fh PORT=380h-38fh PORT=3D0H-3D4H CHOICE="CP12" LINK PORT=348h-34fh PORT=380h-38fh PORT=390h-3a7h PORT=3D0H-3D4H FUNCTION="CP6/CP12 - I/O RANGE E" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to CP12 if a CP12 module is installed at this number. Set to OFF if no CP6 or CP12 module is set to this number. If set to CP12 then I/O Range 10 must be set to OFF." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=390h-397h PORT=3d8h-3dbh PORT=39ch-3a7h PORT=3C0H-3C4H CHOICE="CP12" LINK PORT=390h-397h PORT=3d8h-3dbh PORT=39ch-3bbh PORT=3dch-3dfh PORT=3C0H-3C4H FUNCTION="CP6/CP12 - I/O RANGE F" TYPE="GFDCP4" HELP="Set to CP6 if a CP6 module is installed at this number. Set to OFF if no CP6 module is set to this number." CHOICE="OFF" SUBTYPE="DIS" DISABLE=YES CHOICE="CP6" LINK PORT=3a8h-3bbh PORT=3dch-3dfh PORT=2F8H-2FCH SOFTWARE(1) = "Consult the GammaLink FAX Hardware Reference documentation to determine the switch and/or jumper settings for the ISA boards."