BOARD ID = "OLIF071" NAME = "OLIVETTI NCU 9162" MFR = "OLIVETTI" CATEGORY = "NET" LENGTH = 333 JUMPER(1) = 9 JTYPE = paired NAME = "SR3" REVERSE = yes LABEL = LOC(1 2 3 4 5 6 7 8 9) "3" "4" "5" "6" "7" "9" "0" "1" "2" FACTORY = LOC(1-9) 000001000 JUMPER(2) = 6 JTYPE = paired NAME = "SR4" LABEL = LOC(6 5 4 3 2 1) "7" "6" "5" "7" "6" "5" FACTORY = LOC(6-1) 001001 SOFTWARE(1) = " To setup the DMA Channel and Interrupt after configuring a board, the software drivers must be notified of the jumper settings. See NCU 9162 Installation Guide for more information. \nEdit the CONFIG.sys file and add the line: \nDEVICE=OL01LC.sys \nDEVICE=OL01DLC.sys with the following parameters:" FUNCTION = "Token-Ring Adapter" TYPE = "NET" CHOICE = "Token-Ring Adapter" LINK IRQ = 9 | 3 | 5 | 6 | 7 | 10 | 11 | 12 | {} INIT = JUMPER(1) LOC(1 2 3 4 5 6 7 8 9) 000001000 | 100000000 | 010000000 | 001000000 | 000100000 | 000010000 | 000000100 | 000000010 | 000000001 INIT = SOFTWARE(1) "-i(number adapter)9" | "-i(number adapter)3" | "-i(number adapter)4" | "-i(number adapter)5" | "-i(number adapter)6" | "-i(number adapter)7" | "-i(number adapter)10" | "-i(number adapter)11" | "-i(number adapter)12" LINK DMA = 5 | 6 | 7 SIZE = word INIT = JUMPER(2) LOC(6 5 4 3 2 1) 001001 | 010010 | 100100 INIT = SOFTWARE(1) "-d(number adapter)5" | "-d(number adapter)6" | "-d(number adapter)7"