;Rev Date Name Comment ;------------------------------------------------------------------ ;1.00 15.03.90 DM Initial release ; BOARD ID = "TCC0080" NAME = "American Power UPS Monitor Card model AP9500" MFR = "APC" CATEGORY = "COM" SLOT = ISA8OR16 LENGTH = 100 SKIRT = NO READID = NO COMMENTS = "revision 1.00" SWITCH (1) = 4 NAME = "Config Switch" STYPE = DIP VERTICAL = YES REVERSE = NO LABEL = LOC(1-4) "IO Port" "Lo Battery" "S/D Status" "AC Failure" FACTORY = LOC(1-4) 1010 COMMENTS = "Note that the card ON and OFF\n positions are revsersed from figure." SOFTWARE (1) = "The UPS Monitor Card configuration file\n SERVER.CFG must be created in the SYS:SYSTEM\n directory of the file server hard drive.\n It must be edited as an ASCII text file.\n It will contain the following statements:\n\n UPS TYPE=1" ;Function descriptions start here FUNCTION = "UPS Interface" TYPE="COM" SUBFUNCTION = "IO Port" TYPE="COM" CHOICE="0x231h" LINK PORT = 231h-238h SHARE = NO INIT = SWITCH(1) LOC(1) 0 INIT = SOFTWARE(1) "UPS IO=231" CHOICE="0x240h" LINK PORT = 240h-247h SHARE = NO INIT = SWITCH(1) LOC(1) 1 INIT = SOFTWARE(1) "UPS IO=240" SUBFUNCTION = "Lo Bat Signal" TYPE = "COM" CHOICE = "Closed" LINK INIT = SWITCH(1) LOC(2) 0 INIT = SOFTWARE(1) "UPS DOWN=3" CHOICE = "Open" LINK INIT = SWITCH(1) LOC(2) 1 INIT = SOFTWARE(1) "UPS DOWN=3" SUBFUNCTION = "S/D Status" TYPE = "COM" CHOICE = "Off" LINK INIT = SWITCH(1) LOC(3) 0 INIT = SOFTWARE(1) "UPS WAIT=15" CHOICE = "On" LINK INIT = SWITCH(1) LOC(3) 1 INIT = SOFTWARE(1) "UPS WAIT=15" SUBFUNCTION = "AC Fail Signal" TYPE = "COM" CHOICE = "Closed" LINK INIT = SWITCH(1) LOC(4) 0 CHOICE = "Open" LINK INIT = SWITCH(1) LOC(4) 1