; Technology Concepts Ltd ; Grange Estate ; Cwmbran ; Gwent ; NP44 3XR ; Tel: +44 (0)633 872611 ; Fax: +44 (0)633 872329 ; ; ISA CC4, CC/4B ; CFG Version 1.0a BOARD ID ="TCL0403" ;Product ID NAME = "CC/4, CC/4B Adapter (ISA) PAL HCASARH4" MFR = "Technology Concepts Ltd" CATEGORY = "COM" SLOT = ISA8OR16 AMPERAGE = 1000 SKIRT = NO READID = NO IOCHECK = INVALID DISABLE = UNSUPPORTED COMMENTS = "The CC4 cards provide 4 asynchronous serial ports" HELP = "The CC4 adapters do not support full automatic configuration. The adapter supports a number of emulation and address options which are set via an 8 way switch. The adapters supports the following IRQs : 3, 4, 5, 7, 9, 10, 11, 12, 15." SWITCH(1) = 8 STYPE = DIP NAME = "SW1" REVERSE = NO VERTICAL = NO LABEL = LOC(1-8) "1" "2" "3" "4" "5" "6" "7" "8" FACTORY = LOC(1-8) 00010010 JUMPER(1) = 9 NAME = "LK2 IRQ" JTYPE = TRIPOLE VERTICAL = NO REVERSE = YES LABEL = LOC(1-9) "2" "3" "4" "5" "7" "10" "11" "12" "15" FACTORY = LOC(1-9) n1nnnnnnn ;IRQ 3 FUNCTION = "Emulation / Base Address" COMMENTS = "Select the required emulation mode and base address" CHOICE = "AST 1A0H" LINK PORT=01a0H-019fH INIT=SWITCH(1) LOC (1-8) 10100000 CHOICE = "AST 2A0H" LINK PORT=02A0H-029fH INIT=SWITCH(1) LOC (1-8) 10100001 CHOICE = "Arnet 180H" LINK PORT=0180H-01c2H INIT=SWITCH(1) LOC (1-8) 10110010 CHOICE = "Arnet 280H" LINK PORT=0280H-02c2H INIT=SWITCH(1) LOC (1-8) 10110011 CHOICE = "Hostess 280H" LINK PORT=0280H-029fH INIT=SWITCH(1) LOC (1-8) 10010100 CHOICE = "Hostess 280H" LINK PORT=0280H-02bfH INIT=SWITCH(1) LOC (1-8) 10010101 FUNCTION = "Interrupt Level" COMMENTS = "The CC card can be configured to one of nine interrupt levels. Use the 'Change Resource' option to set the required level. The interrupt level is set via link block LK2." CHOICE = "Choice of : 3, 4, 5, 7, 9, 10, 11, 12, 15" FREE IRQ = 3 | 4 | 5 | 7 | 9 | 10 | 11 | 12 | 15 SHARE = NO TRIGGER = EDGE INIT = JUMPER(1) LOC (1-9) 1nnnnnnnn | n1nnnnnnn | nn1nnnnnn | nnn1nnnnn | nnnn1nnnn | nnnnn1nnn | nnnnnn1nn | nnnnnnn1n | nnnnnnnn1 CHOICE = "Do not use an interrupt " FREE INIT = JUMPER(1) LOC (1-9) nnnnnnnnn