;--------------------------------------------------------; ; * * Future Domain TMC-7000EX SCSI Host Bus Adapter * * ; ; * * Future Domain Corporation * * ; ; * * Copyright (c) 1990-1992 * * ; ; * * All Rights Reserved * * ; ; * * Version 1.6 * * ; ; * * Part Number #84-000345 * * ; ;--------------------------------------------------------; BOARD ID = "WDC2001" ;Product ID NAME = "Future Domain TMC-7000EX EISA SCSI Controller " MFR = "Future Domain Corporation" CATEGORY = "MSD" ;Mass Storage Device SLOT = EISA ;Fits in EISA slot only READID = YES ;EISA ID registers'values are valid BUSMASTER = 50 IOCHECK = INVALID ;EISA IOCHKERR bit is not supported DISABLE = UNSUPPORTED ;EISA ENABLE bit is not supported COMMENTS = "Future Domain TMC-7000EX Configuration File Version 1.6" HELP = "Future Domain Customer Service 2801 McGaw Ave. Irvine, CA 92714 (714) 253-0440 8AM-5PM (PST) " IOPORT(1) = 0zC85h INITVAL = xxxxxxxxb ;AutoConfiguration Register 1 IOPORT(2) = 0zC86h INITVAL = xxxxxxxxb ;AutoConfiguration Register 2 IOPORT(3) = 0zC87h INITVAL = 0000xxxxb ;AutoConfiguration Register 3 FUNCTION = "Adapter Options" TYPE = "CST,Future Domain Corp" ; Max of 40 characters, blank fill SUBFUNCTION = "Protocol Mode" ; after terminating message with '$' CHOICE = "DACB Protocol" ; Change CST to STD for Standard message SUBTYPE = "DACB00" FREE PORT = 0zC80h-0zCFFh INIT = IOPORT(3) LOC(3-0) 0001 ;Set EX in DACB Mode CHOICE = "ASC Protocol, 300H" SUBTYPE = "ASC300" FREE PORT = 0zC80h-0zCFFh PORT = 300h-302h INIT = IOPORT(3) LOC(3-0) 0110 ;Set EX in ASC Mode, 300H CHOICE = "ASC Protocol, 310H" SUBTYPE = "ASC310" FREE PORT = 0zC80h-0zCFFh PORT = 310h-312h INIT = IOPORT(3) LOC(3-0) 1000 ;Set EX in ASC Mode, 310H CHOICE = "ASC Protocol, 320H" SUBTYPE = "ASC320" FREE PORT = 0zC80h-0zCFFh PORT = 320h-322h INIT = IOPORT(3) LOC(3-0) 0100 ;Set EX in ASC Mode, 320H CHOICE = "ASC Protocol, 340H" SUBTYPE = "ASC340" FREE PORT = 0zC80h-0zCFFh PORT = 340h-342h INIT = IOPORT(3) LOC(3-0) 0010 ;Set EX in ASC Mode, 340H CHOICE = "ASC Protocol, 350H" SUBTYPE = "ASC350" FREE PORT = 0zC80h-0zCFFh PORT = 350h-352h INIT = IOPORT(3) LOC(3-0) 0000 ;Set EX in ASC Mode, 350H CHOICE = "ASC Protocol, 360H" SUBTYPE = "ASC360" FREE PORT = 0zC80h-0zCFFh PORT = 360h-362h INIT = IOPORT(3) LOC(3-0) 1010 ;Set EX in ASC Mode, 360H CHOICE = "ASC Protocol, 370H" SUBTYPE = "ASC370" FREE PORT = 0zC80h-0zCFFh PORT = 370h-372h INIT = IOPORT(3) LOC(3-0) 1100 ;Set EX in ASC Mode, 370H CHOICE = "ASC Protocol, 380H" SUBTYPE = "ASC380" FREE PORT = 0zC80h-0zCFFh PORT = 380h-382h INIT = IOPORT(3) LOC(3-0) 1110 ;Set EX in ASC Mode, 380H SUBFUNCTION = "BIOS Address" CHOICE = "0DC000H - 0DFFFFH" FREE INIT = IOPORT(1) LOC(3-0) 1000 CHOICE = "0D8000H - 0DBFFFH" FREE INIT = IOPORT(1) LOC(3-0) 0111 CHOICE = "0D4000H - 0D7FFFH" FREE INIT = IOPORT(1) LOC(3-0) 0110 CHOICE = "0D0000H - 0D3FFFH" FREE INIT = IOPORT(1) LOC(3-0) 0101 CHOICE = "0CC000H - 0CFFFFH" FREE INIT = IOPORT(1) LOC(3-0) 0100 CHOICE = "0C8000H - 0CBFFFH" FREE INIT = IOPORT(1) LOC(3-0) 0011 CHOICE = "0C4000H - 0C7FFFH" FREE INIT = IOPORT(1) LOC(3-0) 0010 CHOICE = "0C0000H - 0C3FFFH" FREE INIT = IOPORT(1) LOC(3-0) 0001 CHOICE = "Disabled" FREE INIT = IOPORT(1) LOC(3-0) 0000 ;Disable BIOS Access SUBFUNCTION = "Interrupt Request Level" CHOICE = "IRQ 15" SUBTYPE = "IRQ15" FREE IRQ = 15 TRIGGER = EDGE INIT = IOPORT(1) LOC(5-4) 11 CHOICE = "IRQ 14" SUBTYPE = "IRQ14" FREE IRQ = 14 TRIGGER = EDGE INIT = IOPORT(1) LOC(5-4) 10 CHOICE = "IRQ 12" SUBTYPE = "IRQ12" FREE IRQ = 12 TRIGGER = EDGE INIT = IOPORT(1) LOC(5-4) 01 CHOICE = "IRQ 10" SUBTYPE = "IRQ10" FREE IRQ = 10 TRIGGER = EDGE INIT = IOPORT(1) LOC(5-4) 00 SUBFUNCTION = "Bus Preempt Time" CHOICE = "32 BCLKS" FREE INIT = IOPORT(1) LOC(7-6) 01 CHOICE = "64 BCLKS" FREE INIT = IOPORT(1) LOC(7-6) 10 FUNCTION = "SCSI Channel" TYPE = "SCS,CHA" SUBFUNCTION = "Adapter SCSI ID" CHOICE = "SCSI ID = 7" FREE INIT = IOPORT(2) LOC(2-0) 111 CHOICE = "SCSI ID = 6" FREE INIT = IOPORT(2) LOC(2-0) 110 CHOICE = "SCSI ID = 5" FREE INIT = IOPORT(2) LOC(2-0) 101 CHOICE = "SCSI ID = 4" FREE INIT = IOPORT(2) LOC(2-0) 100 CHOICE = "SCSI ID = 3" FREE INIT = IOPORT(2) LOC(2-0) 011 CHOICE = "SCSI ID = 2" FREE INIT = IOPORT(2) LOC(2-0) 010 CHOICE = "SCSI ID = 1" FREE INIT = IOPORT(2) LOC(2-0) 001 CHOICE = "SCSI ID = 0" FREE INIT = IOPORT(2) LOC(2-0) 000 SUBFUNCTION = "SCSI Parity" CHOICE = "Enabled" FREE INIT = IOPORT(2) LOC(3) 1 CHOICE = "Disabled" FREE INIT = IOPORT(2) LOC(3) 0