BOARD ID = "NICC105" NAME = "National Instruments GPIB-PCIIA Interface Board" MFR = "NATIONAL INSTR CORP" CATEGORY = "COM" SLOT = ISA8 READID = NO LENGTH = 110 ;11.05cm = 4.35inches AMPERAGE = 490 ;0.490 Amps SKIRT = NO COMMENTS = "GPIB-PCIIA EISA configuration file Version 2.0; For further information call National Instruments at 1-800-433-3488." HELP = "Sorry, no help available." SWITCH(1) = 9 NAME = "Base I/O Address" STYPE = DIP VERTICAL = NO REVERSE = YES LABEL = LOC(1-9) "I0" "I1" "I2" "A14" "A13" "X" "X" "7210" "PCIIA" FACTORY = LOC(1-9) 000111101 INITVAL = LOC(1-9) XXXXXXXX1 ;set for PCIIA mode COMMENTS = "The base I/O address is determined by the settings of the board DIP switch (U2) positions 1-7. The factory setting is for base address 2B8h. Position 8 switches the chip emulation mode between 7210 and 9914. Leave this switch in the 7210 position for normal operation with NI driver software. Position 9 switches the board emulation mode between PCII and PCIIA. For PCII mode, use the PCII configuration file, !NICC205.CFG." JUMPER(1) = 6 NAME = "DMA (W2)" JTYPE = PAIRED VERTICAL = NO REVERSE = YES LABEL = LOC(1-6) "DACK1" "DRQ1" "DACK2" "DRQ2" "DACK3" "DRQ3" FACTORY = LOC(1-6) 110000 ;Factory defaults - DACK1,DRQ1 COMMENTS = "The DMA channel used is determined by this jumper. Note that both the DRQ (request) and DACK (acknowledge) jumpers must be set to the same channel if that channel is to be used." JUMPER(2) = 6 NAME = "IRQ Level (W3)" JTYPE = PAIRED VERTICAL = NO REVERSE = YES LABEL = LOC(1-6) "IRQ2" "IRQ3" "IRQ4" "IRQ5" "IRQ6" "IRQ7" FACTORY = LOC(1-6) 000001 ;Factory default is IRQ7 COMMENTS = "The IRQ level (2, 3, 4, 5, 6, or 7) is determined by this jumper. The GPIB-PCIIA supports shared interrupts." FUNCTION = "GPIB-PCIIA Interface" SUBFUNCTION = "Base I/O Address" COMMENTS = "The base I/O address is selected through this resource. Note that since this address uses negative logic, if your screen or report shows you a binary representation of the switch, the ones and zeroes will be reversed. The 'ON' and 'OFF' settings given by the configuration utility are correct." CHOICE = "2E1" LINK PORT = 02E1h INIT = SWITCH(1) LOC(4-7) 1111 CHOICE = "22E1" LINK PORT = 22E1h INIT = SWITCH(1) LOC(4-7) 1011 CHOICE = "42E1" LINK PORT = 42E1h INIT = SWITCH(1) LOC(4-7) 0111 CHOICE = "62E1" LINK PORT = 62E1h INIT = SWITCH(1) LOC(4-7) 0011 SUBFUNCTION = "DMA Channel" CHOICE = "1" LINK DMA = 1 INIT = JUMPER(1) LOC(1-6) 110000 CHOICE = "2" LINK DMA = 2 INIT = JUMPER(1) LOC(1-6) 001100 CHOICE = "3" LINK DMA = 3 INIT = JUMPER(1) LOC(1-6) 000011 CHOICE = "Disabled" LINK INIT = JUMPER(1) LOC(1-6) 000000 SUBFUNCTION = "Interrupt Request Line" CHOICE = "7" LINK IRQ = 7 SHARE = YES INIT = JUMPER(2) LOC(1-6) 000001 INIT = SWITCH(1) LOC(1-3) 000 CHOICE = "2" LINK IRQ = 2 SHARE = YES INIT = JUMPER(2) LOC(1-6) 100000 INIT = SWITCH(1) LOC(1-3) 101 CHOICE = "3" LINK IRQ = 3 SHARE = YES INIT = JUMPER(2) LOC(1-6) 010000 INIT = SWITCH(1) LOC(1-3) 001 CHOICE = "4" LINK IRQ = 4 SHARE = YES INIT = JUMPER(2) LOC(1-6) 001000 INIT = SWITCH(1) LOC(1-3) 110 CHOICE = "5" LINK IRQ = 5 SHARE = YES INIT = JUMPER(2) LOC(1-6) 000100 INIT = SWITCH(1) LOC(1-3) 010 CHOICE = "6" LINK IRQ = 6 SHARE = YES INIT = JUMPER(2) LOC(1-6) 000010 INIT = SWITCH(1) LOC(1-3) 100 CHOICE = "Disabled" LINK INIT = JUMPER(2) LOC(1-6) 000000 INIT = SWITCH(1) LOC(1-3) 111