Problem:

I am unable to trap the PRINT SCREEN key (on an IBM extended
keyboard, such as on an IBM AT) when pressed simultaneously with the
ALT, SHIFT, or CTRL key. However, these can be trapped, with the
exception of CTRL+PRINT SCREEN, within the QuickBASIC editing
environment.

These keys can be trapped using GW-BASIC Interpreter Version 3.20. The
following is a code example:

KEY 15, CHR$(&H04) + CHR$(&H37)
KEY(15) ON
ON KEY(15) GOSUB keytrap
idle: GOTO idle
keytrap:
   PRINT "CONTROL+PRINT SCREEN key sequence trapped"
   RETURN

Response:

This problem results because the value &H80 is missing from the
keyboardflag argument of the KEY statement. You must add this value
whenever you trap the PRINT SCREEN key on an extended keyboard.
Therefore, the correct method for trapping the key is as follows:

KEY 15, CHR$(&H80 + &H04) + CHR$(&H37)
KEY(15) ON
ON KEY(15) GOSUB keytrapidle: GOTO idle
keytrap:
   PRINT "CONTROL+PRINT SCREEN key sequence trapped"
   RETURN