Q58242: FORMAT.COM Cannot Be Directly Run with Parameters

Article: Q58242
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.0,3.0a
Operating System(s): 
Keyword(s): 
Last Modified: 25-OCT-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows versions 3.0, 3.0a 
-------------------------------------------------------------------------------

SYMPTOMS
========

If you create a PIF file that runs the MS-DOS version 3.x FORMAT.COM utility;
the PIF may have a question mark in the Parameters field. When you run the PIF,
enter a: or b: as the parameter, and then choose the OK button, FORMAT.COM will
start and then print the following error message:

  Drive letter must be specified

FORMAT.COM then exits without doing anything.

This PIF file works properly with Windows/386 Versions 2.x.

WORKAROUND
==========

To work around this problem, do not run FORMAT.COM directly; instead, run
FORMAT.COM from the MS-DOS command prompt, or run FORMAT.COM from the file
manager under the Disk Menu.

STATUS
======

Microsoft has confirmed this to be a problem with Windows version 3.0. We are
researching this problem and will post new information here as it becomes
available.

This problem does not occur with MS-DOS version 4.0 or 4.01.

Additional query words: 3.00 3.00a

======================================================================
Keywords          :  
Technology        : kbWin3xSearch kbZNotKeyword3 kbWin300 kbWin300a