Q76090: WPP Err Msg: An Error Occurred While Setup…(with NDW)

Article: Q76090
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.0,3.0a
Operating System(s): 
Keyword(s): 
Last Modified: 06-DEC-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows versions 3.0, 3.0a 
-------------------------------------------------------------------------------

SUMMARY
=======

If you attempt to install the Microsoft Windows Productivity Pack on a machine
that has Norton Desktop for Windows (NDW) installed, you may receive the
following Productivity Pack error message:

  An error occurred while setup was trying to create a group in the Program
  Manager. Exit now and run setup again.

MORE INFORMATION
================

Temporarily Removing the Norton Desktop as the Windows Shell
------------------------------------------------------------

To correctly install the Productivity Pack on a machine with Norton Desktop you
will need to remove Norton Desktop as the Windows shell and replace it with the
Program Manager. Use the following steps to make this change.

1. Run the Windows 3.0 Notepad program.

2. Open the file SYSTEM.INI located in the Windows directory.

3. Edit the "SHELL=" line to read

        SHELL=PROGMAN.EXE

  instead of SHELL=NDW.EXE.

4. Save the modified file and exit Windows.

5. Run the Productivity Pack Setup program as you normally would.

6. You can then change the "SHELL=" line back once the Setup program has
  completed.