Q89217: Working Copy Demonstration of Ami Pro 2.0 May Cause GP Faults

Article: Q89217
Product(s): Microsoft Windows 95.x Retail Product
Version(s): WINDOWS:3.1,3.11
Operating System(s): 
Keyword(s): 
Last Modified: 12-DEC-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows versions 3.1, 3.11 
-------------------------------------------------------------------------------

SUMMARY
=======

Ami Pro has confirmed that after installing the "Working model" of Ami Pro 2.0
under Windows 3.1, general protection (GP) faults may occur when you restart
Windows.

MORE INFORMATION
================

This problem occurs because the following four files are copied by the Ami Pro
installation program into the Windows SYSTEM subdirectory:

- SHELL.DLL

- OLECLI.DLL

- OLESVR.DLL

- COMMDLG.DLL

To correct the problem, expand the four files from the Windows 3.1 disks into the
Windows SYSTEM subdirectory.

Disk locations are as follows:

                 Disk Size
Filename     1.44MB  1.2MB  720K
---------------------------------

SHELL.DL_      4       5       8
OLECLI.DL_     5       4       A
OLESVR.DL_     4       5       8
COMMDLG.DL_    4       4       A

For more information, contact Ami technical support.

Ami Pro 2.0 is manufactured by a vendor independent of Microsoft; we make no
warranty, implied or otherwise, regarding the product's performance or
reliability.

Additional query words: gpf 3.10 3.11 3rdparty demonstration demo

======================================================================
Keywords          :  
Technology        : kbWin3xSearch kbZNotKeyword3 kbWin310 kbWin311
Version           : WINDOWS:3.1,3.11

=============================================================================