SYMPTOMS
========

If a CPIC application calls Set_Conversation_Security_Password (cmscsp) and
specifies a password of zero length, the call will return with error:

  CM_PROGRAM_PARAMETER_CHECK.

CAUSE
=====

The SNA Server CPIC interface on Windows NT, Windows 3.x and OS/2 incorrectly
rejects a zero-length password.

RESOLUTION
==========

Microsoft has modified the following files to correct this problem:

  WCPIC32.DLL - Win32 client CPIC interface
  WINCPIC.DLL - Windows 3.x client CPIC interface
  CPIC.DLL - OS/2 client CPIC interface


STATUS
======

Microsoft has confirmed this to be a problem in SNA Server for Windows NT. This
problem was corrected in the latest SNA Server for Windows NT, 2.11 U.S. Service
Pack. For information on obtaining the Service Pack, query on the following word
in the Microsoft Knowledge Base (without the spaces):

  S E R V P A C K