Q137970: BUG: Precision for a Projected Column Always Reported as 255

Article: Q137970
Product(s): Open Database Connectivity (ODBC)
Version(s): WINDOWS:2.0,3.0
Operating System(s): 
Keyword(s): kbBug kbISS
Last Modified: 27-JUL-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Open Database Connectivity, versions 2.0, 3.0 
-------------------------------------------------------------------------------

BUG# NT: 2350 (QJET)

SYMPTOMS
========

SQLDescribeCol always returns pcbColDef = 255 for a scalar function projected
column of SQL_VARCHAR data type of defined length.

This problem occurs with all 16- and 32-bit Access drivers. This does not happen
with SQL Server drivers.

STATUS
======

Microsoft has confirmed this to be a problem in the Access Driver versions
2.00.2317 and 3.00.2106. We are researching this problem and will post new
information here in the Microsoft Knowledge Base as it becomes available.

MORE INFORMATION
================

To reproduce this problem:

- The 'name' field is of type SQL_VARCHAR of defined length.

- Select name, UCASE(name) from oof

  SQLDescribeCol for column 2 returns pcbColDef = 255.

also

- Select name, {fn UCASE(name)} from oof

  SQLDescribeCol for column 2 returns pcbColDef = 255.

Additional query words: odbc access driver connectivity sql

======================================================================
Keywords          : kbBug kbISS 
Technology        : kbAudDeveloper kbODBCSearch kbODBC300 kbODBC200
Version           : WINDOWS:2.0,3.0
Issue type        : kbbug

=============================================================================