- Microsoft Windows NT Workstation versions 3.5, 3.51 
- Microsoft Windows NT Server versions 3.5, 3.51 
-------------------------------------------------------------------------------


SYMPTOMS
========

OLE applications that create more than 300 interfaces will stop responding after
registering 300 interfaces in the registry.


CAUSE
=====

This is a limitation in the Windows NT 3.51 registry. The registry is limited to
300 interface keys.


STATUS
======

Microsoft has confirmed this to be a problem in Windows NT versions 3.50 and
3.51. This problem was corrected in the latest Windows NT 3.51 U.S. Service
Pack. For information on obtaining the Service Pack, query on the following word
in the Microsoft Knowledge Base (without the spaces):

  S E R V P A C K


Additional query words: RPC OLE VB VC

======================================================================