Q153517: PGC Does Not Look For Current Connections

Article: Q153517
Product(s): Microsoft Systems Management Server
Version(s): winnt:1.0,1.1,1.2
Operating System(s): 
Keyword(s): kbnetwork kbPGC smsgeneral smspgc kbArtTypeINF
Last Modified: 30-JUL-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Systems Management Server versions 1.0, 1.1, 1.2 
-------------------------------------------------------------------------------

SYMPTOMS
========


Program Group Control (PGC) maps new drive connections even if a current
connection already exists.

CAUSE
=====

When running a PGC application that requires a drive letter, PGC does not look
for an existing connection to the server from which the application is being
run. Although PGC detects a universal naming convention (UNC) connection, it
cannot detect a connection that is mapped to a drive letter.

STATUS
======

Microsoft has confirmed this to be a problem in Systems Management Server
version 1.1. It has been fixed in Systems Management Server version 1.2.

Additional query words: prodsms

======================================================================