SYMPTOMS
========

When an X.400 connector is used over a slow link, a number of different problems
can occur. In some cases the message transfer agent (MTA) stops responding and a
DRWATSON log is generated with exception e0020002 or Access Violation c0000005.
One Application Event Log error is:

  MTA error (Event ID = 9405):
  An unexpected error has occurred which may cause the MTA to terminate.
  Error: SBPDSCLS:CB TID=1,calling TID=0. [BASE TCP/IP DRVR 10] (16)

Other symptoms include the following socket errors:

  A sockets error 10060
  (WSAETIMEDOUT) event ID 9215, A sockets error 10051 (WSAENETUNREACH) event ID
  9215, A sockets error 10054 (WSAECONNRESET) event ID 9224.

WORKAROUND
==========

The problem only happens when there is insufficient bandwidth or a high number
of network errors. One workaround is increase the bandwidth available to the
MTA.

STATUS
======

Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 4.0. This problem was corrected in the latest Microsoft Exchange Service
Pack. For information on obtaining the Service Pack, query on the following word
in the Microsoft Knowledge Base (without the spaces):

  S E R V P A C K


Additional query words: RPC X.25 ISDN

======================================================================