Q156298: FIX: Error on Disconnecting from ODBC Desktop Drivers

Article: Q156298
Product(s): Open Database Connectivity (ODBC)
Version(s): 3.4
Operating System(s): 
Keyword(s): 
Last Modified: 26-MAR-2000

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft ODBC Desktop Driver version 3.4 
-------------------------------------------------------------------------------

SYMPTOMS
========

When you disconnect from an ODBC application that uses Access driver version
3.40 or other ODBC desktop drivers, you may receive the following error
message:

  Message Box Title: <appname.exe>
  The instruction at <addr1> referenced a memory at <addr2>.
  The memory could not be written.

WORKAROUND
==========

This problem has been fixed in Msjt3032.dll version 3.00.3213. For information
on how to obtain this file, see the following article in the Microsoft Knowledge
Base:

  Q151186 INF: Updated Jet DLLs Available on MSL


After you download this file, you can copy Msjt3032.dll to your
<%winroot%>\system32 directory.

Additional query words: 3.40 JET MFC exception

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbODBCSearch kbODBCDDKSearch kbODBCDDK340
Version           : :3.4
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================