SUMMARY
=======

If File and Print Services for NetWare (FPNW) is installed on a primary domain
controller (PDC) and must be removed and reinstalled, the NetWare Compatible
Login properties of all such domain users will be lost unless a backup domain
controller (BDC) is present in the domain.

MORE INFORMATION
================

To avoid losing those properties, perform the following steps:

1. Verify that a BDC exists in the domain, and that it has FPNW installed.

2. Before removing FPNW from the PDC, temporarily promote the BDC to a PDC to
  retain the user properties.

3. After FPNW has been successfully removed and reinstalled on the BDC (the
  former PDC), promote it back to PDC.

For more information, see the following article in the Microsoft Knowledge Base:

  ARTICLE-ID: Q150540
  TITLE : FPNW on Domain Must Be Installed on PDC

Additional query words: prodnt
======================================================================