SYMPTOMS
========

When you are logged on as an administrator and try to run an executable from the
Systems Management Server Installer, the following error message appears:

  **
  ERROR
  You do not have access to make the required system configuration
  modifications. Please rerun this installation from an administrators
  account.
  **

CAUSE
=====

This problem may occur when the Systems Management Server Installer attempts to
write to the client's registry and the configuration requires that the registry
contain a subkey that actually has no values in it. This may occur with most
Windows NT services that are installed.

WORKAROUND
==========

Add a value with no data, to allow the subkey to be copied and installed, as in
the following example:

  MainKey
  SubKey
  Value = Keep; REG_SZ; Data=""

STATUS
======

This problem was corrected in the latest version of the Systems Management
Server Installer.

MORE INFORMATION
================

To obtain the latest version of the Systems Management Server Installer, go to
http://www.microsoft.com/smsmgmt/downloads/install.asp.