Q171877: LU Creation Wizard Does Not Accept HEX Data When in HEX Mode

Article: Q171877
Product(s): Microsoft SNA Server
Version(s): WINDOWS:3.0,3.0 SP1
Operating System(s): 
Keyword(s): kbnetwork
Last Modified: 13-JUN-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 3.0, 3.0 SP1, on platform(s):
   - the operating system: Microsoft Windows NT 
-------------------------------------------------------------------------------


SYMPTOMS
========

When you use the LU Creation Wizard to create a range of LUs, you can select
hexadecimal as the Base setting, but the Wizard will not accept hexadecimal data
in the First Extension field.

CAUSE
=====

Snawiz.dll does not accept hexadecimal data even when the hexadecimal mode is
selected.

RESOLUTION
==========

A hotfix to SNA Server for Windows NT, version 3.0 (post SP1) is available to
correct this problem.

STATUS
======

Microsoft has confirmed this to be a problem in SNA Server 3.0 and 3.0 Service
Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0
U.S. Service Pack. For information on obtaining this Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):

  S E R V P A C K

Additional query words:

======================================================================
Keywords          : kbnetwork 
Technology        : kbAudDeveloper kbSNAServSearch
Version           : WINDOWS:3.0,3.0 SP1
Issue type        : kbbug
Solution Type     : kbfix

=============================================================================