SYMPTOMS
========

You attempt to edit the properties of a registered product in Software Metering,
and the following error message is displayed:

  The product was not registered at this site.

You receive no indication of which site the product was registered in.

CAUSE
=====

This behavior occurs because you are attempting to edit a product in a
multi-site Systems Management Server hierarchy. The product was registered in
another site that has replicated to the site that you are currently modifying.

WORKAROUND
==========

To edit this registered product, follow these steps:

1. Open the Systems Management Server Administrators console that is registered
  to open the site where the product was registered.

2. Expand the Tools folder.

3. Right-click Software Metering, point to All Tasks, and then click Start
  Software Metering.

4. Right-click the registered product, and then click Properties.

5. Complete your registered product property changes, and then click OK.

STATUS
======

Microsoft has confirmed this to be a problem in Microsoft Systems Management
Server version 2.0.