Q236996: ICA NetBEUI Workstation May Not Connect

Article: Q236996
Product(s): Microsoft Windows NT
Version(s): winnt:4.0,4.0 SP4
Operating System(s): 
Keyword(s): kbenv
Last Modified: 11-DEC-2001

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft Windows NT Server versions 4.0, 4.0 SP4, Terminal Server Edition 
-------------------------------------------------------------------------------

SYMPTOMS
========

When an initial connection is made to an Independent Computing Architecture
(ICA) NetBEUI workstation, the connection may not succeed. This may only occur
in international versions of Terminal Server with Citrix Metaframe installed.

CAUSE
=====

Because of a timing problem, the NetBIOS session is not initialized in time and
the connection is dropped.

RESOLUTION
==========

To resolve this problem, obtain the latest service pack for Windows NT 4.0,
Terminal Server Edition. For additional information, please see the following
article in the Microsoft Knowledge Base:

  Q152734 How to Obtain the Latest Windows NT 4.0 Service Pack

STATUS
======

Microsoft has confirmed this to be a problem in the Microsoft products that are
listed at the beginning of this article.