Q243384: SNA LU3 Printing Does Not Support 3270 Some Data Stream Orders

Article: Q243384
Product(s): Microsoft SNA Server
Version(s): WINDOWS:2.11 (all versions),3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3
Operating System(s): 
Keyword(s): 
Last Modified: 22-OCT-1999

-------------------------------------------------------------------------------
The information in this article applies to:

- Microsoft SNA Server, versions 2.11 (all versions), 3.0 (all SP), 4.0, 4.0 SP1, 4.0 SP2, 4.0 SP3 
-------------------------------------------------------------------------------

SYMPTOMS
========

SNA LU3 printing does not support the following 3270 data stream orders:

   - Start Field Extended (SFE, X'29')

- Set Attribute (SA, X'28")

- Modify Field (MF, X'2C')

The Start Field (SF, X'1D') order is converted to a blank (X'40').

Additional query words:

======================================================================
Keywords          :  
Technology        : kbAudDeveloper kbSNAServSearch kbSNAServ400 kbSNAServ400SP1 kbSNAServ400SP2 kbSNAServ400SP3
Version           : WINDOWS:2.11 (all versions),3.0 (all SP),4.0,4.0 SP1,4.0 SP2,4.0 SP3
Issue type        : kbinfo

=============================================================================