Power Supply |
|
U. S. |
Outside U. S. |
Input Specifications |
|
|
Nominal Line Voltage
|
100
to 120 VAC |
220
to 240 VAC |
Range Input Line
|
90
to 132 VAC |
180
to 264 VAC |
Frequency Range
|
47
to 63 Hz |
47
to 63 Hz |
Input Power
|
210
Watts |
210
Watts |
Input Current
|
4.5
at 90 VAC |
2.2
at 180 VAC |
Holdup Time
|
16
ms from zero crossing at 120 VAC |
16
ms from zero crossing at 240 VAC |
General Specifications |
|
|
Full Output Rating
|
To
122° F and 5,000 ft
To 90° F and 10,000 ft (derate linearly) |
To
50° C and 1524 m
To 32° C and 3048 m (derate linearly) |
Minimum Load
|
1.0 A on + 5.0 V output
0.2 A on 12 V output |
1.0 A on + 5.0 V output; 0.2 A on 12 V output |
Ambient Temperature Range |
|
|
Operating
|
50° to 122° F |
10° to 50° C |
Storage
|
-40° to 151° F |
-40° to 66° C |
Dielectric Voltage Withstand |
|
|
Input to Ground
|
1500 VAC/1 second |
|
Safety
Standard |
UL 1950; CSA 22.2 #950 or CSA 22.2 #234; TUV/VDE EN 60 950
(VDE0805/11.91); EMKO-TSE (74-SEC) 207/93 |
Input Transient Susceptibility |
Common and Differential Mode (superimposed on AC
line)
|
2500
V, 1 µs, damped sinusoidal
600 V, 10 µs pulse |
Differential Mode
|
20% step change in AC input voltage |