Memory
error codes |
Error
Code |
Description |
Recommended
Action |
| 200-xx |
Invalid
memory configuration |
1.
Verify memory module value compatibility.
2. Reinsert memory in the correct location. |
| 201-xx |
Memory
machine ID test failed |
The following steps apply to error codes 201-xx and 202-xx: 1 Flash the ROM and retest.
2 Replace the memory and retest.
3 Replace the system board and retest. |
| 202-xx |
Memory
system ROM checksum failed |
| 203-xx |
Memory
write/read test failed |
The following steps apply to error codes 203-xx through 210-xx:
|
| 204-xx |
Memory
address test failed |
| 206-xx |
Increment
pattern test failed |
| 210-xx |
Random
pattern test failed |
|
| Diskette drive
error codes |
Error
Code |
Description |
Recommended
Action |
| 600-xx |
Diskette
ID drive types test failed |
The following steps apply to error codes 600-xx through 698-xx:
|
| 601-xx |
Diskette
format failed |
| 602-xx |
Diskette
read test failed |
| 603-xx |
Diskette
write, read, compare test failed |
| 604-xx |
Diskette
random seek test failed |
| 605-xx |
Diskette
ID media test failed |
| 606-xx |
Diskette
speed test failed |
| 607-xx |
Diskette
wrap test failed |
| 608-xx |
Diskette
write-protect test failed |
| 609-xx |
Diskette
reset controller test failed |
| 610-xx |
Diskette
change line test failed |
| 694-xx |
Pin 34
is not cut on 360KB diskette drive |
| 697-xx |
Diskette
type error |
| 698-xx |
Diskette
drive speed not within limits |
| 699-xx |
Diskette drive/media ID
error |
1. Replace media.
2. Run Setup. |
|