                   Installing Internal 
                  Drives 
                  The PC Server 500 
                  supports the following drive types: 
                  
                    - Diskette drive 
                    
 - Hard 
                    disk drive 
                    
 - Rewritable optical disc drive 
                    
 - Tape 
                    drive 
  
                  The server 
                  has hardware that lets you replace a failed hard disk drive 
                  without powering-off the server. Therefore, you have the 
                  advantage of continuing to operate your system while a hard 
                  disk drive is removed or installed. These drives are also 
                  known as hot-swappable drives.
  Hot-swappable drives 
                  have a green LED that shines through the knob on the tray 
                  containing the drive. If the drive has a good electrical 
                  connection upon installation, the LED illuminates. The LED 
                  blinks briefly during power-up, and also blinks if the drive 
                  malfunctions.
  Internal drives are installed in bays. A 
                  diskette drive and a CD-ROM. drive are preinstalled in bay A 
                  in all models. A removable CD storage compartment is shipped 
                  in bay B1. You can install two drives in bay B. You can 
                  install hot-swappable hard disk drives in banks C, D, and E 
                  only. Banks C, D, and E each contain six bays. Bank C supports 
                  up to six drives. However, the total number of SCSI drives 
                  that you can install in bay B and bank C is six. The number of 
                  preinstalled hard disk drives in bank C varies according to 
                  the model you purchased. You can install up to six drives in 
                  bank D and up to six drives in bank E.
  NOTE: The 
                  bank letter-designations are located on both vertical rails on 
                  the front of the server. The bay-slot numbers are located on 
                  the top of bank C and the bottom of bank E.
 
   
  A cover plate (sometimes called a bezel or face plate ) 
                  covers the front of bay B2 only. If you install a drive that 
                  uses removable media (diskette, optical disc, tape), you might 
                  install and adjust the cover plate after you install the drive 
                  in bay B2.
  Bay Considerations 
                  
                    - Bay 
                    A comes with one SCSI CD-ROM drive and one 3.5-inch, 
                    2.88MB diskette drive. 
                    
 - Bay 
                    B supports: 
                    
                      - One 
                      5.25-inch, full-high, removable-media or 
                      non-removable-media device 
                      
 - or 
                      One 5.25-inch, half-high, removable-media device and one 
                      3.5-inch, half-high, removable-media device 
                      
 - or 
                      Two 3.5-inch or two 5.25-inch, slim-high or half-high, 
                      removable-media devices 
                      
 - NOTE: Only one of 
                      the devices installed in bay B can be a SCSI 
                      device. 
                      
 - You 
                      cannot install hot-swappable drives in bay B. 
                    
  
                     - Bays 
                    C, D, and E support: 
                    
                      - Up to 
                      eighteen 3.5-inch, slim-high, hot-swappable hard disk 
                      drives, or nine 3.5-inch, half-high hard disk 
                      drives 
                      
 - Six 
                      slim-high drives or three half-high drives, or a 
                      combination of both drive sizes. If you use a combination, 
                      remember that one half-high drive uses the equivalent 
                      space of two slim-high drives. 
                      
 - If 
                      you install drives in bank D or E, you will remove the fan 
                      assembly on the rear of the server, install a direct 
                      access storage device (DASD) backplane in banks D and E, 
                      and install an optional 220-watt power supply. 
                    
    
                  Each 
                  backplane has six connectors, to support up to six hard disk 
                  drives.  |