3.220 bytes |
Service Hints & Tips |
Document ID: MCGN-3QNRQQ |
PC Server 315 - Power-up problem
Applicable to: World-Wide
SYMPTOM:
The System fails to power-on initially
- OR -
fails to power-on after the first 5 to 7 power-on cycles.
PROBLEM ISOLATION AIDS:
All of the following must be true for this TIP to apply:
The System is a PC Server 315 type 8638 model KJ0/KS0/PJ0/PS0/PSV/PSW.
The Tantalum Capacitors at System Planer locations C17 and C535 are yellow and have the letter "A" located at the top of the capacitors.
The System failed to power-on initially, or after the first 5 to 7 power-on cycles.
The System will not power up.
The voltage selection switch at the back of the Power Supply is set correctly.
FIX:
- Replace the System Planer with FRU p/n93H4873.
- Refer to the PC Server 315 Hardware Maintenance Manual for assembly details.
Note:
- All FRU stock has been cleared of any affected System Planers World-Wide.
- See RETAIN TIP Record# H121366 for IBM statements relative to component failures.
SAS KEYWORDS:
PSY2 PSY2PLANER UNCLASSIFIED D/T8638
POWER 93H4873
|
Search Keywords |
PSY2, PSY2PLANER, UNCLASSIFIED, D/T8638, POWER, 93H4873 | |
|
Hint Category |
Power, Retain | |
|
Date Created |
12-01-98 | |
|
Last Updated |
15-07-98 | |
|
Revision Date |
14-07-99 | |
|
Brand |
IBM PC Server | |
|
Product Family |
PC Server 315 | |
|
Machine Type |
8638 | |
|
Model |
KJ0; KS0; PJ0; PS0; PSV; PSW | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H162327 | |
|
Reverse Doclinks |