2.712 bytes |
Service Hints & Tips |
Document ID: MCGN-3RMMU8 |
Netfinity 7000 - Power fail LED blinks after replacing power supply (EMEA only)
Applicable to: EMEA
SYMPTOM:
The Power Fail LED at the front of the server continues to blink after replacing one or more failed power supplies.
PROBLEM ISOLATION AIDS:
All of the following must be true for this tip to apply:
- The system is a Netfinity 7000 type 8651 model RH0/RM0/TH0/TM0
- The system has a BIOS level of CZE10A or lower.
- One or more power supplies have been replaced.
- The system has not been powered down during or after the replacement of the power supply(s).
FIX:
Take down the server NOS, power-off, then power-on the server.
DETAIL:
The power-off/power-on cycling of the server will reset the Power Fail LED controller.
NOTE:
If the Power Fail LED continues to blink, continue normal problem determination. Refer to Retain TIP Record # H161771 that covers "Power Supply Fault Isolation on Netfinity 7000".
SAS KEYWORDS:
D/T8651, PSY2, PSY2POWER, POWER SUPPLY, UNCLASSIFIED
|
Search Keywords |
D/T8651, PSY2, PSY2POWER, POWER SUPPLY, UNCLASSIFIED | |
|
Hint Category |
Retain | |
|
Date Created |
12-02-98 | |
|
Last Updated |
15-07-98 | |
|
Revision Date |
14-07-99 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 7000 | |
|
Machine Type |
8651 | |
|
Model |
RH0; RM0; TH0; TM0 | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H162679 | |
|
Reverse Doclinks |