IBM PC330/PC350 - "RPL Halted" error with IBM LAN Adapter for Ethernet
Applicable to: World-Wide
Symptom:
IBM PC 300 Series 6577 and 6587 may exhibit an "RPL Halted" error message at the beginning of the RIPL operation, immediately following the POST test beep when using the IBM LAN Adapter for Ethernet.
Problem Isolation Aids:
Configure the adapter to perform the RIPL function, then configure the System Setup Startup Options to start the system from the network instead of the floppy drive or hardfile. When the system is restarted, the "RPL Halted" message appears after POST.
Fix:
Do not replace hardware. Verify that the network, system, and adapter configurations are correct.
An updated EPROM has been developed and made available to eliminate this failure. This is a customer-installable replacement which is ordered as a FRU part number. Check the EPROM installed, it may be a 28 pin 'DIP' module or a 32 pin 'PLCC' module. Order the replacement FRU as detailed.
28 pin DIP module FRU 8134986
32 pin PLCC module FRU 8134997
THE EPROM UPDATE IS PROVIDED TO ELIMINATE THE SYMPTOM DESCRIBED ABOVE. OTHER LAN RELATED PROBLEMS SHOULD BE ISOLATED USING NORMAL PROBLEM DETERMINATION PROCEDURES OR DIRECTED TO THE IBM SUPPORT STRUCTURE FOR ASSISTANCE.
SAS KEYWORDS:
PSY2 D/T65XX 6577 6587
IBMPC PSVP PSVPADPT PSY2ADPT
D/T6587 PC 350 PC350 PC300
PC 330 PC330 43790 PSVPCOMM
PSY2COMM
|
Search Keywords |
| |
|
Hint Category |
Adapter Cards, Error Messages, Retain | |
|
Date Created |
20-01-97 | |
|
Last Updated |
21-05-98 | |
|
Revision Date |
19-05-99 | |
|
Brand |
IBM PC | |
|
Product Family |
PC 330, PC 350 | |
|
Machine Type |
6577, 6587 | |
|
Model |
Various | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H046626 | |
|
Reverse Doclinks |