2.268 bytes |
Service Hints & Tips |
Document ID: MCGN-3SXR7G |
Netfinity 7000 - Cooling failure light blinks slowly
Applicable to: World-Wide
SYMPTOM:
The system cooling failure light (amber light located at the front Control Panel) blinks slowly.
PROBLEM ISOLATION AIDS:
All of the following must be true for this tip to apply:
- The system is a IBM Netfinity 7000 type 8651 model RM0, TM0, RH0, TH0.
- All cooling fans are operate properly.
- All power supplies are operating properly.
- The fan jumpers (Fan3:J2J3, Fan4:J2J4 located near the left front edge of the Planar / Fan2:J5G2, Fan1:J5G1 located near right front edge of the Planar) are securely in place.
- All internal cables are secure.
- System diagnostics pass.
FIX:
Replace the Power Backplane Cover with FRU p/n12J3266 using normal warranty parts replacement procedures.
NOTE:
Refer to the "Power Backplane Removal" section of the "Hardware Maintenance Manual Supplement" publication
S06J-0791-00 p/n 06J0791 for power backplane cover removal and installation instructions.
SAS KEYWORDS:
PSY2, D/T8651, UNCLASSIFIED, COOLING FAILURE, PSY2PART, P/N12J3266
|
Search Keywords |
PSY2, D/T8651, UNCLASSIFIED, COOLING FAILURE, PSY2PART, P/N12J3266 | |
|
Hint Category |
Retain | |
|
Date Created |
26-03-98 | |
|
Last Updated |
14-07-98 | |
|
Revision Date |
13-07-99 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 7000 | |
|
Machine Type |
8651 | |
|
Model |
RM0; TM0; RH0; TH0 | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H163045 | |
|
Reverse Doclinks |
USA=A, EMA=A, AFE=A, Owning B.U.: USA, Date last altered: A98/03/17 |