2.587 bytes |
Service Hints & Tips |
Document ID: MCGN-3ZHJEE |
Netfinity 7000 M10 - Incorrect movement of SMU'S menu selection bar during Telnet
Applicable to: World-Wide
Source: RETAIN tip H164979
Abstract: INCORRECT MOVEMENT OF SMU'S MENU SELECTION BAR DURING TELNET
Incorrect movement of menu selection bar on the System Management Utility Remote Video Screen when connected to a Netfinity 7000 M10 through a Telnet session.
SYMPTOM:
Telnet to a Netfinity 7000 M10 server and connect to the System Management Utility. Start a remote video session and monitor remote POST. Through the client, enter the system set-up (F1 Key) of the host machine. Menu bar positioning between host and the client will be identical when scrolling down on the set-up menu, but when scrolling up on the remote video set-up menu, the menu bar will not move correctly on host although it moves correctly on client.
WORKAROUND:
Changing the terminal emulation on the Telnet browser may resolve this. As another solution, the user may use a web browser instead of a Telnet browser.
SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, TELNET, BROWSER, MENU, BAR, SYSTEM, MANAGEMENT, UTILITY, 8680COMM, 8680OPER, 8680PROG
|
Search Keywords |
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, TELNET, BROWSER, MENU, BAR, SYSTEM, MANAGEMENT, UTILITY, 8680COMM, 8680OPER, 8680PROG | |
|
Hint Category |
Retain | |
|
Date Created |
22-10-98 | |
|
Last Updated |
14-01-99 | |
|
Revision Date |
14-01-2000 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 7000 M10 | |
|
Machine Type |
8680 | |
|
Model |
ALL | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H164979 | |
|
Reverse Doclinks |
Date last altered: A98/10/26 |