|
2.295 bytes |
Service Hints & Tips |
Document ID: MCGN-42BK69 |
|
This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose. |
Server 95 - Fast/Wide SCSI-2 Adapter configuration conflict
Applicable to: AP-S, Canada, LA, United States
Source: RETAIN tip H021000
Abstract: Fast/Wide SCSI-2 Adapter configuration conflict
TEXT:
A configuration conflict may occur when upgrading a SCSI adapter w/cache (FRU P/N85F0000*), with a SCSI-2 FAST/WIDE adapter on Type 3 8595/9595 systems. After this change, fixed disks greater than 1 GB will no longer be recognized.
The only systems known to be affected are 8595/9595 model OMT, (80486 50 Mhz processor, FRU P/N57F1597*) which uses the Type 3 Reference Diskette with a hardfile greater than 1GB installed.
8595 and 9595 systems, which use the Type 1,2 or 4 IML Diskette and other PS/2 systems are not affected.
A self executing software fix is now available from the National Support Center by calling 1-800-772-2227 and requesting the Server Support Group.
* FRU P/N85F0000 will automatically substitute to P/N85F0063 and FRU P/N57F1597 will automatically substitute to P/N82G2484.
SAS KEYWORDS:
PSY2, D/T9595, PSY2FDSK, PSY2ADPT, PSY2, FAST, WIDE
|
Search Keywords |
PSY2, D/T9595, PSY2FDSK, PSY2ADPT, FAST, WIDE | |
|
Hint Category |
Retain | |
|
Date Created |
17-11-98 | |
|
Last Updated |
17-11-98 | |
|
Revision Date |
17-11-99 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Server 95 | |
|
Machine Type |
9595, 8595 | |
|
Model |
Various | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H021000 | |
|
Reverse Doclinks |
Date created: O94/04/15 |