Netfinity 5500 M10 - Error LED reset to off
Applicable to: World-Wide
Source: RETAIN tip H164903
TEXT:
Error LED reset to off.
SYMPTOMS:
Error LED may/will remain "On" if the AC is not removed.
PROBLEM ISOLATION AIDS:
- The system is a Netfinity 5500 M10, Type 8661, any model.
- The system's service processor is BIOS level 20.
FIX:
Next release of the service processor BIOS for 8661.
WORKAROUND:
After repairing a system problem that was indicated by lit LED on the diagnostic panel, the system should be unplugged for at least 20 seconds so that the error LED can be reset to off.
SAS KEYWORDS:
PSY2, D/T8661, NETFINITY, SERVICER ONLY, SERVICE, PROCESSOR, LED, BIOS 20, 8661BRD, 8661MCD, 8661MISC, 102287, 102317, 103409
|
Search Keywords |
PSY2, D/T8661, NETFINITY, SERVICER ONLY, SERVICE, PROCESSOR, LED, BIOS 20, 8661BRD, 8661MCD, 8661MISC, 102287, 102317, 103409 | |
|
Hint Category |
Retain | |
|
Date Created |
20-10-98 | |
|
Last Updated |
14-01-99 | |
|
Revision Date |
14-01-2000 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 5500 M10 | |
|
Machine Type |
8661 | |
|
Model |
ALL | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H164903 | |
|
Reverse Doclinks |
Date last altered: A98/12/03 |