Servers - Server diagnostics will hang if USB device is attached
Applicable to: World-Wide
Source: RETAIN tip H164722
SYMPTOM:
Diagnostics will not run with USB device attached to the Server.
PROBLEM ISOLATION AIDS:
- The system is any one of the following Netfinity servers:
Netfinity 5500 server, Type 8660, all Models.
Netfinity 5500 M10 server, Type 8661, all Models.
Netfinity 7000 M10 server, Type 8680, all Models.
- The system hangs when running Diagnostics.
FIX:
No fix planned.
WORKAROUND:
To run diagnostics do the following:
1. Shutdown your operating system and turn off the server.
2. Disconnect any USB devices from the server.
3. Ensure a standard keyboard and standard mouse is connected to the server.
4. Restart your server.
5. Run Diagnostics.
SAS KEYWORDS:
PSY2, NETFINITY, UNCLASSIFIED, USB, DIAGNOSTICS, ERROR, KEYBOARD, MOUSE, H164722
|