2.722 bytes |
Service Hints & Tips |
Document ID: RMIE-3JEAZP |
IBM PC330/PC350 - False error code with QAPlus/2
Applicable to: World-Wide
Problem :
IBM PC 300 Series 6577 and 6587 may intermittently exhibit a false CPU diagnostic error code when the System Board test is performed using QAPlus/2. The error code displayed is "MBD061."
Problem Isolation Aids :
The false error code is displayed when all of the System Board tests are selected in QAPlus/2. The error will occur when the CPU is tested.
Solution :
If the user suspects a system board problem exists, the IBM Personal Computer Diagnostic diskette (QAPlus/PRO) should be used to diagnose the failure.
The IBM PC 300/700 Diagnostic diskette (QAPlus/PRO) is created by using the Diskette Factory included in the systems preloaded software.
Perform the System Board diagnostic routines using QAPlus/PRO. If all of the system board tests pass, assume that the "MBD061" error indication under QAPlus/2 is false. If the test does fail in QAPlus/PRO, continue normal problem determination procedures.
SAS KEYWORDS :
PSY2 D/T65XX 6577 6587
IBMPC PSVP PSVPBRD PSY2BRD
D/T6587 PC 350 PC350 PC300
PC 330 PC330 42844 PSVPDIAG
PSY2DIAG
|