2.462 bytes |
Service Hints & Tips |
Document ID: MCGN-3RVMFJ |
PC Server 330 - On-board diagnostics fails continuous loop test
Applicable to: World-Wide
SYMPTOM:
The on-board ROM based diagnostics reports a 2620 error (RAID configuration error).
PROBLEM ISOLATION AIDS:
All of the following must be true for this tip to apply:
- The system is a IBM PC Server 330 type 8640 model PT0/PB0/PM0.
- The on-board ROM based diagnostics has been engaged in a continuous loop mode to test the RAID disk subsystem.
- There are devices connected/configured on the on-board ServeRAID II Controller.
FIX:
This problem will be fixed in a future Firmware Flash Update for the on-board ROM based diagnostics. The Flash update is
anticipated to be available by June, 1998.
WORKAROUND:
Use the on-board ROM based diagnostics for problem determination as it applies to isolating components only. DO NOT use it as a run-in exerciser (continuous loop).
SAS KEYWORDS:
PSY2, D/T8640, UNCLASSIFIED, PSY2DIAGS
|
Search Keywords |
PSY2, D/T8640, UNCLASSIFIED, PSY2DIAGS | |
|
Hint Category |
Diagnostics, Retain | |
|
Date Created |
20-02-98 | |
|
Last Updated |
25-11-98 | |
|
Revision Date |
05-11-99 | |
|
Brand |
IBM PC Server | |
|
Product Family |
PC Server 330 | |
|
Machine Type |
8640 | |
|
Model |
PT0; PB0; PM0 | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H162800 | |
|
Reverse Doclinks |