3.021 bytes |
Service Hints & Tips |
Document ID: RMIE-38RG4J |
PC Server 300 - PCI Mylex RAID Adapter and IBM 2GB FirmWare drives
Applicable to: World-Wide
Symptom
The 2GB drive cannot be terminated and there are no F/W cable (in-line) terminators available.
The 2GB drive can be terminated with a single jumper.
Resolution
Use the latest Server 300 BIOS.
Terminate the last drive on the SCSI-bus.
The jumpers are located below the F/W SCSI connector of the drive.
----------Jumper for switching termination on/off
: jumper set: termination on
V jumper removed: termination off
o o o o o o o o
o o o o o o o o o
Related Products
Starfire drives, PC Server 300, SCSI-2 Streaming RAID Adapter
|
Search Keywords |
IBM HardDrives, RAID, SCSI | |
|
Hint Category |
Hard Drives, RAID | |
|
Date Created |
24-08-95 | |
|
Last Updated |
31-10-98 | |
|
Revision Date |
27-10-99 | |
|
Brand |
IBM PC Server | |
|
Product Family |
PC Server 300 | |
|
Machine Type |
8640 | |
|
Model |
Various | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
| |
|