2.239 bytes |
Service Hints & Tips |
Document ID: MCGN-3ZXKD4 |
Netfinity 7000 M10 - Memory errors not in log if "all banks" memory test selected
Applicable to: World-Wide
Source: RETAIN tip H165150
Abstract:
Memory errors not in log if "all banks" memory test selected.
SYMPTOM:
Error not logged.
PROBLEM ISOLATION AIDS:
- The system is a Netfinity 7000 M10 server, Type 8680, any model.
- The system's diagnostics pass.
- The system is configured with PC Doctor version 21A.
FIX:
PC Doctor Diagnostic version 23A.
WORKAROUND:
Use diagnostic's log or SMI log to view.
DETAILS:
Test individual memory bank as indicated by screen or SMI error.
SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, DIAGNOSTIC, PC, DOCTOR, 103126, 21A, 23A, ERROR, LOG, 8680ERR
|
Search Keywords |
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, DIAGNOSTIC, PC, DOCTOR, 103126, 21A, 23A, ERROR, LOG, 8680ERR | |
|
Hint Category |
Retain | |
|
Date Created |
05-11-98 | |
|
Last Updated |
14-01-99 | |
|
Revision Date |
14-01-2000 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 7000 M10 | |
|
Machine Type |
8680 | |
|
Model |
ALL | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H165150 | |
|
Reverse Doclinks |
Date last altered: A98/11/02 |