3.234 bytes |
Service Hints & Tips |
Document ID: SCOD-43DN86 |
Netfinity 5000 - ASM DIMM Information Display Error
Applicable to: World-Wide
Source: RETAIN tip H165545
Abstract:
NETFINITY'S ASM DIMM INFORMATION DISPLAY ERROR
SYMPTOM:
Connect to a Netfinity 5000 through Netfinity Manager.
Open the Netfinity Service Manager. Open the Advanced System Management Service. Open the Configuration Information window.
Open the Memory Information window.
Results:
Note that the DIMM information is shown in reverse order. For example, the information for physical DIMM slot 1 on the
Planar is displayed as DIMM 4 in the Memory Information window.
PROBLEM ISOLATION AIDS:
The system is a Netfinity 5000 server Type 8659, any Model.
FIX:
The fix is available by downloading the Advanced Systems Management Processor Firmware Update Diskette v1.01 (Build Level 38A), or later, which is available at the following URL:
http://www.pc.ibm.com/searchfiles.html
WORKAROUND:
Use Netfinity System Information Tools to get memory information.
SAS KEYWORDS:
PSY2, D/T8659, NETFINITY, UNCLASSIFIED, SERVICE, PROCESSOR, MEMORY, DIMM, SLOT, ADVANCED, SYSTEM, MANAGEMENT
|
Search Keywords |
PSY2, D/T8659, NETFINITY, UNCLASSIFIED, SERVICE, PROCESSOR, MEMORY, DIMM, SLOT, ADVANCED, SYSTEM, MANAGEMENT | |
|
Hint Category |
Retain | |
|
Date Created |
21-12-98 | |
|
Last Updated |
14-01-99 | |
|
Revision Date |
14-01-2000 | |
|
Brand |
IBM PC Server | |
|
Product Family |
Netfinity 5000 | |
|
Machine Type |
8659 | |
|
Model |
all | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
H165545 | |
|
Reverse Doclinks |
Date last altered: A98/12/28 |