2.125 bytes |
Service Hints & Tips |
Document ID: JBAR-3YTPKP |
IBM PC300PL (Type 6862, 6892) - System locks during POST with error 162 displayed with LS-120 drive
Applicable to: World-Wide
SYMPTOM:
System locks during POST with error 162 displayed. System will not enter BIOS setup utility. System must be turned off, then on to regain function. When this is done, problem re-occurs.
CONFIGURATION:
Problem occurs when base unit has the LS-120 drive installed in any position on the IDE controller. Problem occurs at BIOS level NVJT32A or older. The problem may occur with ANY operating system, as it occurs during POST. No special applications or drivers are required for the failure to occur.
RESOLUTION:
Problem is resolved by removing the LS-120 drive, flashing the BIOS of the system to NVJT33A or above, then re-installing the LS-120 drive.
Click on the following link to obtain the latest BIOS for this system: 
|
Search Keywords |
| |
|
Document Category |
Non-IBM Hardware/Software | |
|
Date Created |
30-09-98 | |
|
Last Updated |
01-10-98 | |
|
Revision Date |
30-09-99 | |
|
Brand |
IBM PC | |
|
Product Family |
PC 300PL | |
|
Machine Type |
6862, 6892 | |
|
Model |
all | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
| |
|