IBM Power Subsystem Firmware Update
for use with
System Firmware Release 235 Level 214 ONLY:
pSeries 9119-590
pSeries 9119-595
iSeries 9406-595
pSeries 9118-575
DATE: January 2, 2007
Table of Contents
1.0 Firmware Change History
2.0 General Information
2.0.0 Where to Obtain the Firmware
2.0.1 How to Load the Firmware
2.1 Cautions and Important Notes
| Code Level |
Description |
BP235_205 |
GA6: Service Pack 5
- Fix for Frame Number problem on HPS
- Fix for timing problem during HPS reset
- Fix for problem servicing cable faults
- Fix for multiple System Reference Codes reported for single CEC power supply fail
|
BP235_185 |
GA6: Service Pack 4
- Fixes for erroneous System Reference Codes reported against I/O drawer power supplies
- Fixes for erroneous System Reference Codes reported against CEC power supplies
|
BP235_174 |
GA6: Service Pack 3
|
BP235_157 |
GA6 Service Pack 1:
- Fixes for problems related to concurrent and non-concurrent I/O drawer adds
|
BP235_156 |
GA6: General Availability
- Support for the 9119-590/595 and 9406-595 redundant Service Processors with dynamic failover
|
The Power Subsystem Firmware level contained in this update is:
BP235_205
The individual internal Power FRU code levels are:
| Internal FRU Name | Code Level |
| (hex) | (decimal) |
| BPC 196 | 000A | 10 |
| BPC DSP | A387 | 41863 |
| BPR | A01A | 40986 |
| CEC MDA-S | 039B | 923 |
| CEC DCA-SQ | 0010 | 16 |
| Node DCA-SIH | 0008 | 8 |
| I/O DCA-BC | 003E | 62 |
| I/O MDA-BC | 0005 | 5 |
| I/O DCA-BCS | 0039 | 57 |
| I/O MDA-BCS | 0406 | 1030 |
| HPS DCA-F | 003D | 61 |
| HPS MDA-F | 0394 | 916 |
This package provides updated Power Subsystem Firmware for use on the following systems only:
- pSeries 9119-590
- pSeries 9119-595
- pSeries 9118-575
- pSeries Powered Expansion Rack
- pSeries High Performance Switch in any of the above Systems
- pSeries High Performance Switch Multi-rack Configuration
- iSeries 9406-595
Do not use on any other systems. The package contains downloadable
Firmware for some or all of the following power subsystem components: BPC
(Bulk Power Controller), BPR (Bulk Power Regulator), DCA (Distributed Converter
Assembly and MDA (Motor Drive Assembly).
This firmware can be found at the following locations:
IMPORTANT NOTE:
Before attempting to load this firmware please ensure that your HMC (Hardware Management Console) software
has been upgraded to the appropriate version. HMC version information can be found at:
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html
The instructions regarding how to query, obtain, install and remove firmware
levels can be found on the following IBM Infocenter Page:
Getting server firmware and power subsystem firmware fixes and upgrades
- Never Turn Off the UEPO switch (red switch) During the Power Subsystem
Firmware Update Process --
the update will fail, and the process must be repeated. Also,
the power component being loaded could be permanently disabled.
- Never Log Off of the HMC During the Power Subsystem Firmware Update
Process --
the update will fail, and the process must be repeated.
- Service any existing problems with the Power Subsystem prior to
attempting to load Power Subsystem Firmware from the HMC. Outstanding
problems can cause the Power Subsystem to be in an N-mode power state
(which means there has been a loss of redundancy) and can prevent the HMC
from being able to load the Power Subsystem Firmware.