                         While general field upgrades of 59x systems at 
  firmware release level SF230 (or earlier) to firmware release level SF235 
  are not being performed, this release level was shipped on 59x systems shipping
  from manufacturing between October 2005 and May 2006. 
                             
                                                                        
                              
                        Concurrent update to the latest service pack within 
  the SF235 Release is  available to customers via ECA 828. 
                             
                                                                        
                                                        
                                                    
                               Model 590 and 595 Recommendations: 
                                
                               Systems Currently at Release Level SF230: 
       Customers not requiring the function being provided in later firmware
 releases  can stay at their current level and continue to receive fixes
via  Service  Packs to minimize disruption to their operations. Product Engineering
 recommends  the concurrent installation of ECA 827 (minimum level SF230_156)
 during your  next firmware maintenance window.  
                                
                               Customers with model 59x servers at firmware
 level SF230_xxx  who would like to enable the Redundant FSP/Node failover
 capabilities or upgrade their firmware to a new release boundary (i.e. SF240_xxx) 
 for any reason should call 1-800-IBM-SERV and request ECA815.  IBM
will  dispatch a Service Representative to complete this upgrade for you.
                         
                                
                               Systems Currently at Release Level SF235: 
       Product Engineering recommends the concurrent installation of ECA
828   (minimum  level SF235_206) during your next firmware maintenance window.
                           
                                                                        
                                                                        
         
                        If customers with systems at the SF235 release
   level would like to learn more about what is contained in the latest 
service  pack, visit  http://www14.software.ibm.com/webapp/set2/firmware/gjsn?mode=30&page=01SF235_214_160.html 
                                                                        
                                                                        
         
                         
                               NOTE:  Note: For 9119 systems
with  release level SF235 installed, an ECA is not required to upgrade to
release  level SF240. 
                                
                                |