| Input-Inhibited Field Error Codes |
|
| Error Code |
Explanation |
User Response |
| 610 |
Fatal communication check |
Ensure that the coaxial cable is securely connected to the 3174/3274 control unit. |
| 670 |
Hardware time out |
Record the information and call your system representative. |
| 671 |
Device initialization error |
Record the information and call your system representative. |
| 672 |
HCON internal error |
Record the information and call your system representative. |
| 673 |
HCON internal error |
Record the information and call your system representative. |
| 674 |
Hardware error |
Record the information and call your system representative. |
| 675 |
HCON internal error |
Record the information and call your system representative. |
| 676 |
HCON internal error |
Record the information and call your system representative. |
| 677 |
Device address already enabled |
Record the information and call your system representative. |
| 678 |
Device address not enabled |
Record the information and call your system representative. |
| 679 |
HCON internal error |
Record the information and call your system representative. |
| 680 |
HCON internal error |
Record the information and call your system representative. |
| 681 |
HCON internal error |
Record the information and call your system representative. |
| 683 |
Selective reset issued |
The host has issued a selective reset. Consult your local host administrator. |
| 684 |
Power-on reset in progress |
Press the RESET key to clear the error. Continue with the host session. |
| 687 |
The adapter has shut down |
Record the information and call your system representative. |
| 688 |
HCON internal error |
Record the information and call your system representative. |
| 689 |
HCON internal error |
Record the information and call your system representative. |
| 690 |
HCON internal error |
Record the information and call your system representative. |
| 703 |
Unsupported request received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 705 |
SNF field of transmission header out of sequence |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 706 |
Command chaining error |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 707 |
Bracket state violation |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 708 |
Data traffic not yet started |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 709 |
Half-duplex protocol violation |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 711 |
Session limit exceeded |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 713 |
Session already bound |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 714 |
Session not bound |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 715 |
Session not activated |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 716 |
BIND parameter list too short |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 717 |
BIND support level not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 718 |
BIND PLU protocol not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 719 |
BIND SLU protocol not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 720 |
BIND Common protocol not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 723 |
BIND LU type not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 724 |
BIND screen size not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 725 |
BIND cryptography not supported |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 726 |
Negative response received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 727 |
Exception request received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 728 |
Read command with end bracket (EB) or not in licensed internal code (LIC) + CD |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 729 |
Read Partition received while the device was in retry state |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 731 |
BIND inbound maximum RU size not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 732 |
BIND outbound maximum RU size not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 750 |
Not valid 3270 command received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 751 |
Not valid character set value for SFE, MF, or SA order |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 752 |
Address out of range for SBA, RA, or EUA order |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 753 |
Data follows RM, RMA, RB, or EAU command; RA has not valid character; not valid attribute value or type for SFE, MF, or SA; not valid parameter for SA (SCS) |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 755 |
Not valid 3270 order received or not valid DBCS character code received. |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 756 |
SF type not valid or unsupported |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 759 |
Error in SF length |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 761 |
Not valid PID value for SF |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 769 |
HCON internal error |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 771 |
Not valid command in SF |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 791 |
Not valid SHF or SVF parameter (SCS) |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 792 |
Not valid SLD parameter (SCS) |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 793 |
Spooling print job failed (SCS) |
Record the information and contact the host system programmer. |
| 797 |
SO/SI are not in correct pair |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 798 |
SO/SI are received in DBCS field or GE is received in DBCS field or DBCS subfield |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
| 799 (SBCS) |
HCON internal error |
Record the information and call your system representative. |
| 799 (DBCS) |
Start address points at DBCS low byte, not valid character attribute value in DBCS field or DBCS subfield, or not valid stop address |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |